6. From the Main Menu, select Radio Module Configuration and press
Configuration window is displayed.
Station Type
Station Rank (1-1000)
Center Frequency
Security Password 1
Security Password 2
Security Password 3
Security Password 4
Security Password 5
Scrambling Code
Acquisition Code
Config Test Minutes
Base Station Only Parameters
Repeater Mode
System Symmetry Type
Dynamic Polling Level (1-100)
Remote Station Only Parameters
Remote Unit RF Group (0-63)
Reboot New RF configuration
Save Current Config to Flash
• Select Station Type. Choose Base Station.
• Select Station Rank. Enter the total number of remote units in your wireless network. For
example, if you have only one remote unit, enter "1". If there are 20 remote units, enter "20".
• Select Center Frequency. Press the up or down arrow keys to choose the frequency. All units
in a wireless network must be set to the same center frequency.
• Select Acquistion Code. Enter a value from 0–15. (All units in the same network must have
the same acquisiton code.)
• Select Security Password 1. Type a security password in hexadecimal for the unit.
• Enter the remaining passwords. (All units in the same network must have the same set of five secu-
rity passwords.)
• Select Config Test Minutes. Enter a time in minutes, for example, 10. The unit will automat-
ically reboot when this time period expires, and uses the settings stored in flash memory instead of
current settings.
• Select Reboot New RF configuration and press
window is displayed.
7. Log in to the unit. (Enter supervisor for the password). The Main Menu is displayed.
8. Select Radio Module Configuration and press
is displayed.
9. Select Save Current Config to Flash and press
memory and displayed on the menu. The word
10. Press
Esc to go back to the Main Menu.
11. Select Logout to exit or press
18
Radio Module Configuration
New
-> Remote Unit
1
2.4400 GHz
(Hex)
1
(Hex)
10
(Hex)
100
(Hex)
1000
(Hex)
10000
(Hex)
0
(0-15)
1
(1-120)
10
off
Asymmetric
0
Press Enter to Execute
Press Enter to Execute
Success
.
Esc
Enter.
Current
Flash
Remote Unit
Remote Unit
1
1
2.4400 GHz
2.4400 GHz
1
1
10
10
100
100
1000
1000
10000
10000
0
0
1
1
10
10
off
off
Asymmetric
Asymmetric
0
0
The unit reboots and the Login
Enter.
The Radio Module Configuration window
Enter.
The new settings are stored in flash
Enter.
appears on the screen.
Hopper Plus 120-24 Installation & Configuration Guide