Setting the Acquisition Code

An acquisition code is a unique code contained within the preamble of a transmitted message. Units search
the air for messages that begin with a particular acquisition code. Messages without the correct code are
treated as interference and are rejected by a unit. Messages with the correct code are accepted and
processed. Acquisition codes serve to isolate units from each other, especially when several units operate in
close proximity or at the same frequency in a multiple-sector or multi-cell environment. All units in the same
network must have the same acquisition code in order to communicate with each other.
To set the acquisition code
1. From the Main Menu, select Radio Module Configuration and press
Configuration menu is displayed.
Station Type
Station Rank (1-1000)
Center Frequency
Security Password 1
Security Password 2
Security Password 3
Security Password 4
Security Password 5
Scrambling Code
Acquisition Code
Config Test Minutes
Base Station Only Parameters
Repeater Mode
System Symmetry Type
Dynamic Polling Level (1-100)
Remote Station Only Parameters
Remote Unit RF Group (0-63)
Reboot New RF configuration
Save Current Config to Flash
2. Select Acquisition Code and press
3. Type the Acquisition code (0-15).
4. Press
. The new setting is displayed in the "New" column.
Enter
5. Select Reboot New RF Configuration and press
120-24 Login menu is displayed. The unit now runs using the "Current" acquisition code for the amount
of time specified by the Current Test Minutes.
6. To save the current setting(s) to flash memory, log in, go to the Main Menu, and select Radio Module
Configuration, Save Current Config to Flash. See
Configurations, page
7. Press
to exit to the Main Menu.
Esc
DEC 2000 Rev 02
Radio Module Configuration
(Hex)
(Hex)
(Hex)
(Hex)
(Hex)
(Hex)
(0-15)
-> 0
(1-120)
Enter
79.
New
Current
Remote Unit
Remote Unit
1
1
2.4400 GHz
2.4400 GHz
1
1
10
10
100
100
1000
1000
10000
10000
0
0
0
30
30
off
off
Asymmetric
Asymmetric
1
0
0
Press Enter to Execute
Press Enter to Execute
. The data field highlights.
. The unit reboots and the Hopper Plus
Enter
Radio Module Configuration
. The Radio Module
Enter
Flash
Remote Unit
1
2.4400 GHz
1
10
100
1000
10000
0
0
30
off
Asymmetric
0
Rebooting and Saving RF Module
71