HEAT EXCHANGER
2. Measure:
•
Filler cap opening pressure
Cap opens with a pressure below the specified
pressure → Replace.
Cap opening pressure:
SEA6050
Measurement steps:
•
Attach the cooling system tester 1 to the coolant
filler cap 2.
Cooling system tester:
•
Apply the specified pressure for 10 seconds and
make sure there is no pressure drop.
INSTALLATION
1. Install:
•
Heat exchangers
Use the rivet gun.
6-4
COOL
95 ~ 125 kPa
2
(0.95 ~ 1.25 kg/cm
, 14 ~ 18 psi)
90890-01325, YU-24460-01