FAULT LOCATION TABLE

NOTE:
When more than one problem is detected, the water temperature indicator light flashes in the pattern of the lowest
numbered problem. After that problem is corrected, the water temperature indicator light flashes in the pattern
of the next lowest numbered problem. This continues until all of the problems are detected and corrected.
No.
0
∗ If the CDI unit is working properly, the water tem-
perature indicator light flashes in this pattern when
the engine is turned on.
1
2
3
0.75 s
:
Warning light is on
ON
FAULT LOCATION TABLE
Patterns
SEA8720
SEA8730
SEA8740
Repeats
2.5 s
SEA8750
:
Warning light is off
OFF
8-46
ELEC
Condition
Water temperature
indicator light is good.
If the water tempera-
ture indicator light does
not come on replace it.
Overheat.
Shorting of the water
temperature sensor is
detected.
Discontinuity of the
variable resistor (grip
warmer) is detected.
s : Second
+
Reference
Refer to "SIGNAL
SYSTEM".
Refer to "WATER
TEMPERATURE
SENSOR".
Refer to "VARI-
ABLE RESISTOR
(GRIP
WARMER)".