Wiring The System For Power; Electrical Plug Configuration - Wine Guardian WG15 Installation, Operation And Maintenance Manual

Wine cellar cooling systems through-the-wall wine cellar cooling systems
Table of Contents

Advertisement

Wiring the System for Power

The electrical outlet and wiring installation must meet the national and local building codes.
DO:
 Match the electrical outlet to the plug provided on the Wine Guardian. 
 Provide dedicated circuit and wiring for the system.
 Match the wiring and breaker size to the rated load as shown on the serial
plate and in this guide. See sample serial plate illustration below.
DO NOT:
 DO NOT MODIFY THE PLUGS IN ANY WAY! 
 Do not use extension cords.
The electrical power supply must be 115 volt AC 1 phase 60 cycle, depending on the model
of the system, and cannot vary more than +/- 4% or damage may occur to the unit.

Electrical Plug Configuration

electronic detection to automatically cut off power to the unit when a current leakage condition is
detected in the systems power cord.
Once power is shut off, the device will not be able to be reset until the unsafe current leakage
situation is resolve. Power is restored by the "reset" button on the cord's power head.
WARNING
ELECTRICAL SHOCK HAZARD
Model No. WG15
Electrical
240/1/50
Locked Rotor Amps
9
Compressor RLA
0.9
Condenser Fan Amps
0.2
Evaporator Fan Amps
0.2
Condensate Heater
N/A
Total Unit Amps (w/o opt.)
1.3
Air Innovations, 7000 Performance Drive, North Syracuse, New York 13212
00 1 315-452-7400 * Fax: 00 1 315-452-7420
IMPORTANT
Plug the system into the wall outlet. Gently pull on the plug to make
sure it is tight.
This is the configuration of the factory supplied plug for European
applications. Alterations to this plug for alternative power sources
would require factory approval. LCDI (leakage current detection
interrupter) power cord, which specifies that single phase portable air
conditioning units contain a protection device to reduce the risk of an
arc fault occurring in the power cord. These provide a reliable way to
prevent the risk of fire due to a damaged power cord. They feature
Serial No.
Electric Heat Amps (Opt.)
2.1
2.9
Min. Circuit Amps (w/o opt.)
Refrigerant
R-134-A
System Charge
256 g
Test Pressure 1896 k Pa
WG15 is Patent Pending
23