Review The Packing Slip To Verify; Check The Unit For; General Description - Wine Guardian WG15 Installation, Operation And Maintenance Manual

Wine cellar cooling systems through-the-wall wine cellar cooling systems
Table of Contents

Advertisement

Review the Packing Slip to Verify:

 Model number
 Factory-installed options
 System accessories
If any items listed on the packing slip do not match your order information, contact the place
of purchase immediately.
Check the unit
 An electrical power cord (factory installed on condenser side)
 The Easy Mount™ Through-the-Wall mounting sleeve.
 Accessories such as condenser air duct collar or duct collar kit, and optional controls, if
ordered.
 The EasyMount™ Through-the-Wall mounting sleeve.

General Description

The Through-the-Wall Wine Guardian cooling system is a professional grade, self-contained
climate control system designed specifically for the storage of wine at cellar temperatures. It is
designed for easy installation and operation. Wine Guardian uses digital electronic controls and
environmentally friendly R-134a refrigerant. All 50Hz Wine Guardian equipment is CE certified.
Each system is factory installed with a sealed, CE-approved power cord and plug that can be
mounted on either end of the cooling system. Wine Guardian products are made in the USA.
The Wine Guardian Through-the-Wall system is completely self-contained and includes an
integral air cooled condenser. The system is functionally divided into two sections, the evaporator
or cooling section, and the condenser or heat rejection section. Each section contains a coil to add
or remove heat and a fan to move the air through the coil and into our or out of the cellar or
adjacent space.
Air from the cellar first enters the cooling coil. Air passes through the cooling coil and is cooled
by the refrigerant inside the coil. This causes any excess humidity in the air to condense and be
captured in the drain pan and internally evaporates as it comes in contact with the integral
condensate removal coil. Air then enters the fan where it is pressured and discharged out of the
system. The thermostat, located on the system, or through the optional remote interface controller,
turns the cooling on and off as needed to maintain its set point.
The compressor and condenser section are activated whenever the system is cooling. The
condenser fan draws air from the surrounding or ambient space. The airflows through the
condenser coil where it absorbs heat from the refrigerant in the coil. The air is finally discharged
out of the system by the condenser fan, and can be ducted outside or to an unused space by an
optional condenser duct kit.