Alarm Codes
High temperature
alarm
"flashing"
Low temperature alarm
"flashing"
High humidity alarm
"flashing"
Low humidity alarm
"flashing"
!1 = High Pressure
Switch Fault
!2 = CS (Condensate
Switch Fault)
Press the "Up" or "Down" arrow once to change
screen from alarm to normal Temperature and
Humidity indication. "Hi Temp" will remain on
screen until temperature falls below the High
Temperature Alarm setpoint (Setting 3).
Press the "Up" or "Down" arrow once to change
screen from alarm to normal Temperature and
Humidity indication. "Lo Temp" will remain on
screen until temperature rises above the Low
Temperature Alarm set point (Setting 2).
Press the "Up" or "Down" arrow once to change
screen from alarm to normal Temperature and
Humidity indication. "Hi Hum" will remain on screen
until humidity falls below the High Humidity Alarm
setpoint (Setting 5).
Press the "Up" or "Down" arrow once to change
screen from alarm to normal Temperature and
Humidity indication. "Lo Hum" will remain on screen
until humidity rises above the Low Humidity Alarm
set point (Setting 4).
THIS ALARM FORCES THE SYSTEM
TO SHUT DOWN
This alarm forces the system to shut down
Press the "Up" or "Down" arrow once to
change screen from alarm to normal
Temperature and Humidity indication.
"!1" will remain on screen until the High Pressure
reset switch has been reset. See the trouble
shooting guide page 60 for "Instructions to Reset
High Pressure Switch"
THIS ALARM FORCES THE SYSTEM
TO SHUT DOWN
This alarm forces the system to shut down
Press the "Up" or "Down" arrow once to
change screen from alarm to normal
Temperature and Humidity indication.
"!2" will remain on screen until the CS
(condensate switch) fault is resolved and reset
33