Wiring the System for Power

The electrical outlet and wiring installation must meet the national and local building codes.
DO:
 Match the electrical outlet to the plug provided on the Wine Guardian. 
 Provide dedicated circuit and wiring for the system.
 Match the wiring and breaker size to the rated load as shown on the serial
plate and in this guide. See sample serial plate illustration below.
DO NOT:
 DO NOT MODIFY THE PLUGS IN ANY WAY! 
 Do not use extension cords.
The electrical power supply must be 115 volt AC 1 phase 60 cycle, depending on the model
of the system, and cannot vary more than +/- 4% or damage may occur to the unit.

Electrical Plug Configuration

Once power is shut off, the device will not be able to be reset until the unsafe current leakage situation
is resolve. Power is restored by the "reset" button on the cord's power head.
26
WARNING
ELECTRICAL SHOCK HAZARD
IMPORTANT
Plug the system into the wall outlet. Gently pull on the plug to make
sure it is tight.
To comply with the UL STD 484 this system contains a factory supplied
LCDI (leakage current detection interrupter) power cord, which specifies
that single phase portable air conditioning units contain a protection device
to reduce the risk of an arc fault occurring in the power cord. These provide
a reliable way to prevent the risk of fire due to a damaged power cord. They
feature electronic detection to automatically cut off power to the unit when a
current leakage condition is detected in the systems power cord.