Restrictions In Use With The M-48 At 96Khz - Roland M-5000 Reference Manual

Hide thumbs Also See for M-5000:
Table of Contents

Advertisement

Restrictions in Use with the M-48 at
96kHz
When the sampling rate is set at 96 kHz, the number of audio
channel that a REAC slave device present at the REAC port where
the M-48 is connected can send to the M-5000 is 32. Sending more
than 32 channels produces noise.
(Because of the M-48's control signals, obtaining a band on
100BASE-TX ample enough for the REAC slave device to send 40
audio channels at 96 kHz is not possible.)
REAC device sending 40 channels at 96 kHz
5 M-5000
5 S-4000S-4000
5 S-4000M
5 S-2416 with cascade connection
5 R-1000
Connection Producing Noise (Not OK)
S-4000S-4000
REAC SLAVE
/40ch/96kHz
M-48
S-4000D
REAC A
MASTER
M-5000 96kHz
REAC MASTER
Settings for the REAC Ports and Expansion Slots
Connection Producing No Noise 1 (OK)
Set the system's sampling rate at 48 kHz.
S-4000S-4000
REAC SLAVE
/40ch/48kHz
M-48
S-4000D
REAC A
MASTER
M-5000
48kHz
REAC MASTER
213