Control System and External Device Connections

The SMP 351 can be configured and controlled from the Remote RS-232 port (see
figure 3,
E
page 18) using SIS commands and DataViewer via Telnet port 23. A standard Web
browser can be used for control and configuration from the LAN port. Because the LAN
port must be connected for streaming output, Extron recommends using it for configuration,
remote control, and firmware upgrades.
USB storage device – You can attach an optional external USB storage device to the
B
front or rear USB ports to save recorded files. The storage device can be any standard
external hard drive or USB flash drive formatted with a compatible file system.
NOTE: The SMP 351 can detect and record to USB storage devices using FAT32,
VFAT long file name extensions, EXT2, EXT3, or EXT4 file systems.
USB keyboard and mouse – Connect a keyboard and mouse to the two USB type A
C
ports. With a keyboard and mouse connected, the user can toggle <CTL+ALT+S> the
HDMI output (see
browser view.
Digital I/O – Connect to the four 3.5 mm, 5-pole captive screw connectors to provide
D
user-defined digital inputs or outputs (see
Configurator
Remote — To control the SMP 351 using SIS commands over RS-232, connect the
E
host RS-232 cable to the rear panel (see
screw connector for bi-directional (±5 V) serial host control. The default protocol for this
port is as follows:
9600 baud
no parity
8 data bits
1 stop bit
no flow control (handshaking).
Reset button and LED — Press the reset button to reset the SMP 351. There are
P
several reset modes to return to user-defined configuration settings or to return all
settings back to factory defaults. The LED indicates the desired reset mode, and
provides the reset status during the reset operation (see
on page 16).
RJ-45 Ethernet connector (LAN) — Use a standard Ethernet cable to connect to a
Q
network. The default network settings are:
IP Address:
Subnet Mask:
Default Gateway: 0.0.0.0
DHCP:
NOTE: To connect the SMP 351 directly to a computer Ethernet port, use a
crossover Ethernet cable (see
on page 12) or the front panel USB mini-B Config port (see
figure
3,
) between the standard preview output and the internal
N
on page 149).
192.168.254.254
255.255.0.0
OFF
Connection Options
figure
About the FlexOS App - Digital I/O
figure
3,
on page 12) with a 3-pole captive
E
SMP 351 Rear Panel Reset
on page 156).
SMP 351 • Installation
8,
on
B
15