Control, Bidirectional - Serial (Com); Control, Bidirectional - Lan (Ethernet); Control, Unidirectional - Ir/Serial - Extron electronics IPCP Pro PCS1 xi Setup Manual

Table of Contents

Advertisement

IPCP Pro PCS1 xi • Setup Guide (Continued)
Control, Bidirectional — Serial (COM)
Rear Panel
COM
Tx Rx
G
I
R/S
S
S
G
Heat Shrink
Over Shield Wires
To 3-pole
COM port
Control, Bidirectional — LAN (Ethernet)
Insert Twisted
Pair Wires
RJ-45
Connector
Pins:
8
7
6
5
4
3
2
1
Rear
Panel
Activity
LAN
LED
The control processor is assigned a unique user hardware ID number (MAC address,
for example, 00-05-A6-05-1C-A0). You may need this address during control processor configuration.
A label that indicates the MAC address is located on the rear or side panel of the unit.
Control, Unidirectional — IR/Serial
To a Projector,
Panel Display, or the
IR or RS-232
Wired IR Remote or
RS-232 Port of a
Source Device
6
Serial (COM) Port
3-pole COM
(RS-232)
NOTE: The 3-pole
COM port
supports software
ow control only.
G
Ground
Rx
Receive
Tx
Transmit
TCP/IP
Network
Ethernet
LAN (Ethernet)
Default protocol, public ports:
• IPCP IP address: 192.168.254.250
• Gateway IP address: 0.0.0.0
Link
• Subnet mask: 255.255.255.0
LED
• DNS address: 127.0.0.1
• DHCP client: off
• Link speed and duplex level: autodetected
• Data rates: 10/100/1000Base-T
Rear Panel
CO
O M
Tx
R x
R
G
I R / S
S G
or
Output
Ground
Unidirectional
IR
Select protocol via software.
COM port default protocol:
• 9600 baud
• 8 data bits • 1 stop bit
• no parity
• no ow control
Heat Shrink
RS-232-
Receive (Rx)
Controllable
Transmit (Tx)
Device
Strip wires
3/16" (5 mm) max.
PC
NOTE:
The factory configured passwords for this device
have been set to the device serial number. Passwords
are case sensitive. Performing a Reset to Factory
Defaults reset (see
page 8) sets the passwords to extron.
Default login
credentials:
• Username:
admin or
user
• Password:
extron
IR/Serial Ports
Output options:
• IR (30 kHz to 300 kHz,
with or without carrier signals)
• Unidirectional RS-232
(-)
(+)
(-)
(-)
G
Ground
S
IR Output Signal
(+)
(+)
Two Single IR Emitters
Front Panel
IPCP
COM
I/O
O
O
1
Tx
2
Rx
3
NOTE: If you use cable that
has a drain wire, tie the
drain wire to ground at
both ends.
Reset Modes: a Brief Summary
Front Panel
RO PCS1 xi
O O P
1000 Mbps
Connection
1000
Network is
LINK
active.
ACT
Data is being
sent/received.
00-05-A6-XX-XX-XX
MAC: 00-05-A6-XX-XX-XX
S/N: ####### E######
MAC: 00-05-A6-XX-XX-XX
S/N: ####### E######
Front Panel
IR/S
IR/Serial LED
Lights when signals are
transmitted on the IR/serial port.
To the IR Receiver of a
Projector, Display, or
Source Device
on
MAC
Address

Advertisement