Restoring Factory Default Settings; Restoring Defaults Using Cli - AudioCodes MediaPack MP-124 User Manual

Voip media gateway sip protocol
Hide thumbs Also See for MediaPack MP-124:
Table of Contents

Advertisement

SIP User's Manual
6

Restoring Factory Default Settings

You can restore the device's configuration to factory defaults using one of the following
methods:
Using the CLI (see ''Restoring Defaults using CLI'' on page 215)
Loading an empty ini file (see ''Restoring Defaults using an ini File'' on page 216)
Using the hardware Reset button (see Restoring Defaults using Hardware Reset
Button on page 216)
6.1

Restoring Defaults using CLI

The device can be restored to factory defaults using CLI, as described in the procedure
below.
To restore factory defaults using CLI:
1.
Access the device's CLI:
a.
Connect the device's RS-232 port (refer to the Installation Manual) to COM1 or
COM2 communication port on your PC.
b.
Establish serial communication with the device, using a serial communication
program (such as HyperTerminal
settings:
2.
At the CLI prompt, type the following command to access the configuration mode, and
then press the Enter key:
conf
3.
At the prompt, type the following command to reset the device to default settings, and
then press the Enter key:
RestoreFactorySettings
The CLI commands are shown in the terminal emulation program (e.g., HyperTerminal)
below:
Version 6.2
Baud Rate: 9,600 bps for MP-11x; 115,200 bps for MP-124
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
Figure 6-1: RestoreFactorySettings CLI Command
6. Restoring Factory Default Settings
) with the following communication port
TM
215
February 2011