Distinctive Ringing - AudioCodes MediaPack MP-124 User Manual

Voip media gateway sip protocol
Hide thumbs Also See for MediaPack MP-124:
Table of Contents

Advertisement

7.1.1

Distinctive Ringing

Distinctive Ringing is applicable only to FXS interfaces. Using the Distinctive Ringing
section of the Call Progress Tones auxiliary file, you can create up to 16 Distinctive Ringing
patterns. Each ringing pattern configures the ringing tone frequency and up to four ringing
cadences. The same ringing frequency is used for all the ringing pattern cadences. The
ringing frequency can be configured in the range of 10 to 200 Hz with a 5 Hz resolution.
Each of the ringing pattern cadences is specified by the following parameters:
Burst Ring On Time: Configures the cadence to be a burst cadence in the entire
ringing pattern. The burst relates to On time and the Off time of the same cadence. It
must appear between 'First/Second/Third/Fourth' string and the 'Ring On/Off Time'
This cadence rings once during the ringing pattern. Otherwise, the cadence is
interpreted as cyclic: it repeats for every ringing cycle.
Ring On Time: Specifies the duration of the ringing signal.
Ring Off Time: Specifies the silence period of the cadence.
The Distinctive Ringing section of the ini file format contains the following strings:
[NUMBER OF DISTINCTIVE RINGING PATTERNS]: Contains the following key:
'Number of Distinctive Ringing Patterns' defining the number of Distinctive
Ringing signals that are defined in the file.
[Ringing Pattern #X]: Contains the Xth ringing pattern definition (starting from 0 and
not exceeding the number of Distinctive Ringing patterns defined in the first section
minus 1) using the following keys:
Ring Type: Must be equal to the Ringing Pattern number.
Freq [Hz]: Frequency in hertz of the ringing tone.
First (Burst) Ring On Time [10 msec]: 'Ring On' period (in 10 msec units) for
the first cadence on-off cycle.
First (Burst) Ring Off Time [10 msec]: 'Ring Off' period (in 10 msec units) for
the first cadence on-off cycle.
Second (Burst) Ring On Time [10 msec]: 'Ring On' period (in 10 msec units)
for the second cadence on-off cycle.
Second (Burst) Ring Off Time [10 msec]: 'Ring Off' period (in 10 msec units)
for the second cadence on-off cycle.
Third (Burst) Ring On Time [10 msec]: 'Ring On' period (in 10 msec units) for
the third cadence on-off cycle.
Third (Burst) Ring Off Time [10 msec]: 'Ring Off' period (in 10 msec units) for
the third cadence on-off cycle.
Fourth (Burst) Ring On Time [10 msec]: 'Ring Off' period (in 10 msec units) for
the fourth cadence on-off cycle.
Fourth (Burst) Ring Off Time [10 msec]: 'Ring Off' period (in 10 msec units) for
the fourth cadence on-off cycle.
Note:
SIP User's Manual
In SIP, the Distinctive Ringing pattern is selected according to the Alert-Info
header in the INVITE message. For example:
Alert-Info:<Bellcore-dr2>, or Alert-Info:<http://.../Bellcore-dr2>
'dr2' defines ringing pattern #2. If the Alert-Info header is missing, the default
ringing tone (0) is played.