SIP User's Manual

10.3.3 Remote Alarm Indication Parameters

The Remote Alarm Indication (RAI) parameters are described in the table below.
Parameter
[EnableRAI]
[RAIHighThreshold]
[RAILowThreshold]
[RAILoopTime]

10.3.4 Serial Parameters

The RS-232 serial parameters are described in the table below. (Serial interface is mainly
used for debugging and for SMDI.)
Parameter
[DisableRS232]
EMS: Baud Rate
[SerialBaudRate]
Version 6.2

Table 10-15: RAI Parameters

Enables RAI alarm generation if the device's busy endpoints exceed a
user-defined threshold.
[0] = Disable RAI (Resource Available Indication) service (default).
[1] = RAI service enabled and an SNMP
'acBoardCallResourcesAlarm' Alarm Trap is sent.
High threshold percentage of total calls that are active (busy endpoints).
When the percentage of the device's busy endpoints exceeds this high
threshold, the device sends the SNMP acBoardCallResourcesAlarm
alarm trap with a 'major' alarm status.
The range is 0 to 100. The default value is 90.
Note: The percentage of busy endpoints is calculated by dividing the
number of busy endpoints by the total number of "enabled" endpoints.
Low threshold percentage of total calls that are active (busy endpoints).
When the percentage of the device's busy endpoints falls below this low
threshold, the device sends an SNMP acBoardCallResourcesAlarm
alarm trap with a 'cleared' alarm status.
The range is 0 to 100%. The default value is 90%.
Time interval (in seconds) that the device periodically checks call
resource availability.
The valid range is 1 to 200. The default is 10.

Table 10-16: Serial Parameters

Enables or disables the device's RS-232 port.
[0] = RS-232 serial port is enabled (default).
[1] = RS-232 serial port is disabled.
The RS-232 serial port can be used to change the networking
parameters and view error/notification messages. For information on
establishing a serial communications link with the device, refer to the
Installation Manual.
Note: For this parameter to take effect, a device reset is required.
Determines the value of the RS-232 baud rate.
The valid values include the following: 1200, 2400, 9600 (default),
14400, 19200, 38400, 57600, or 115200.
Note: For this parameter to take effect, a device reset is required.