Get Config; Get Connection; Get Device; Get Dns - AMX SDX-510M-DX Instruction Manual

Solecis digital switchers
Table of Contents

Advertisement

Telnet Commands (Cont.)
Command

GET CONFIG

GET CONNECTION

GET DEVICE

GET DNS

Instruction Manual - Solecis Digital Switchers
Description
Displays the current connection settings.
Example:
>get config
Device number: 7010
Connection Settings
--------------------------------
Mode:
NDP
System Number:
2155
Master IP/URL:
192.168.43.83
Master Port:
1319
Username:
Password:
IP Settings
--------------------------------
HostName:
SDX-510-000-EXB
Type:
DHCP
IP Address:
192.168.43.63
Subnet Mask:
255.255.255.0
Gateway IP:
192.168.43.2
MAC Address:
00:60:9f:99:26:f1
DHCP Server
: 192.168.43.2
Lease Origin
: THU 01/09/2031 12:59:02
Lease Duration
: SUN 01/12/2031 12:59:02 (259200 sec)
Lease Renew
(T1): SAT 01/11/2031 00:59:02 (129600 sec)
Lease Rebind (T2): SUN 01/12/2031 03:59:02 (226800 sec
DNS Servers
--------------------------------
Domain suffix:
amx.internal
Entry 1:
192.168.40.7
Entry 2:
192.168.40.8
Note: The system number and IP addressing information displayed is reflective of actual
operating values, not stored parameters.
Shows the Master connection information.
Example:
>get connection
Connection Settings
------------------------------
Mode:
UDP URL
System Number:
1
Master IP/URL:
192.168.44.53
Master Port:
1319
Username:
Password:
Displays the device number.
Gets the list of DNS entries.
Example:
>get dns
DNS Servers
-------------------------------
Domain suffix:
amx.internal
Entry 1:
192.168.40.7
Entry 2:
192.168.40.8
Note: When the switcher is in DHCP Mode, these are active values, NOT the stored
values that only apply to Static IP Mode.
Appendix A - Telnet (Terminal) Commands