4.
(This step is optional.) Attach fill plates using the #4-40 3/16 inch undercut flat head screws (provided). Be sure to
use the screw holes closest to the front of the tray.
5.
Use wire ties (not provided) to mount the power supply to the rear section of the rack shelf. This step is optional.

Connections and Setup

The following sections describe how to connect your switcher to your network, audio/video sources, and accessories.

Setting the DIP Switches

Use the Configuration DIP switch to enable/disable the LAN ports and set network connectivity. All DIP switches are
initially set to the OFF position. The DIP switches are located on the front panels of the SDX-410-DX and
SDX-810-DX, and on the rear panel of the SDX-510M-DX.

Enabling the LAN 10/100 Ports on the Switcher

The LAN 10/100 ports on the switchers are disabled by default. You can enable the ports by setting #1 DIP switch to ON
(see FIG. 35).

Enabling Network Connectivity on the Switcher

Network connectivity on the switchers is disabled by default. You can enable network connectivity by setting #3 DIP
switch to ON (see FIG. 35).
#1 switch, set to ON to enable
FIG. 35
Config DIP Switch (SDX-410-DX displayed)

Connecting the Switcher to a Video Output

The switchers can transmit a signal simultaneously to both DXLink and HDMI outputs.



Applying Power

Once your have mounted the switcher, set the DIP switches, and connected the appropriate input and output devices to
the ports on the switcher, apply power by connecting the recommended power supply for your switcher. SDX-510M-DX
switchers include a universal power cord, so no external power supply is needed for that model of switcher.
The SDX-410-DX and SDX-810-DX switchers require use of one of the following AMX power supplies (not included):



Toggling Between IP Addressing Modes: DHCP and Static IP

Solecis Digital Switchers support both DHCP and static IP addresses. When the #3 DIP switch is set to ON (see the
CONFIG DIP Switch section on page 15), the switchers automatically use DHCP with link-local fallback. However, you
can use a static IP address which you can set via a Telnet command (SET IP), or you can use the factory default static IP
address. The default static IP address can be recalled at any time by resetting the unit to its factory default configuration.
The default static IP address is 192.168.2.2. The default link-local address is 169.254.2.2. The switcher defaults to the
link-local address if no IP address is obtained from a DHCP server.
The ID Pushbutton can be used to toggle between the DHCP and Static IP Modes.
Perform these steps to toggle between IP addressing modes:
1.
After the switcher boots, press and hold the ID Pushbutton until the STATUS and LINK/ACT LEDs toggle back
and forth in unison approximately 10 times.
30
LAN 10/100 ports
The switcher uses standard HDMI cabling to connect to the HDMI output. Use an HDMI cable to connect the
HDMI OUT port on the rear panel of the device to the display device. (On the SDX-510M-DX, the HDMI
OUT port is located on the front panel.)
The switcher uses category cabling to connect to the DXLink output. See the Important Twisted Pair Cabling
Requirements and Recommendations section on page 25 for information about cable requirements for the
DXLink port. Use category cabling to connect the DXLINK port on the rear panel of the device to the
DXLink input port on a DXLink receiver, Enova DVX switcher, or Enova DGX switcher. (On the
SDX-510M-DX, the DXLINK POWERED port is located on the front panel.)
PSR4.4, 13.5 VDC, 4.4 A Power Supply with 3.5mm Phoenix Connector with Retention Screws (FG423-46)
PSN6.5, 13.5 VDC, 6.5 A Power Supply with (3) 3.5mm Phoenix Connectors (FG423-41)
#3 switch, set to ON to enable
network connectivity
Instruction Manual - Solecis Digital Switchers