Needle Plate Removal; Needle Plate Base Assembly Removal; Needle Plate Base Disassembly - Brother PR600 Service Manual

Professional embroidery machine
Hide thumbs Also See for PR600:
Table of Contents

Advertisement

Main unit
13

Needle plate removal

1. Remove the 2 screws 1, and then remove the needle plate 1.
14

Needle plate base assembly removal

1. Remove the 2 screws 1 to disconnect the cutter link assembly 1.
2. Remove the 2 screws 2, and then remove the needle plate base assembly.
15

Needle plate base disassembly

1. Remove the screws 1, 2, and then remove the rotary hook stopper.
2. Remove the screw 3, and then remove the movable knife and the movable
knife collar.
3. Remove the screw 4, and then remove the fixed knife.
4. Remove the screw 5, and then remove the thread holding plate.
Main parts
1
1
1
2
3
3
4
4
5
5
2
2
1
1
1
2 - 11