Chapter 6. Fru Information (Service Only); Hard Disk Drive Cage - IBM xSeries 200 Hardware Maintenance Manual

Hide thumbs Also See for xSeries 200:
Table of Contents

Advertisement

Chapter 6. FRU information (service
only)
Field Replacement Units (FRUs) should be replaced by
qualified service personnel only.

Hard disk drive cage

Before you begin:
v Read "Safety information" on page 125.
v Review the information in "Before you begin" on page
44.
To remove the hard disk drive cage, do the following:
1. Power-off the server, if it is on.
2. Unplug the server.
3. Remove the front bezel (see "Removing the bezel" on
page 48).
4. Remove the cover (see "Removing the side cover" on
page 46).
5. Remove the support bracket (see "Removing the
support bracket assembly" on page 49).
6. Remove any hard disk drives or drive fillers from the
drives.
7. Disconnect the hard disk drive cables from the system
board.
8. Remove the screws from the front of the hard disk
drive cage.
9. Move the cage slightly in and up until it is free of the
chassis and lift it out of the server.
© Copyright IBM Corp. 2000