tape backup drive, refer to the documentation that
comes with your server or your backup option.
7. The electromagnetic interference (EMI) integrity and
cooling of the server are both protected by having bays
1 through 4 covered or occupied. When you install a
drive, save the EMC shield and filler panel from the
bay, in case you later remove the drive and do not
replace it with another.
8. For a list of supported options for your server, refer to
http://www.ibm.com/pc/us/compat on the World Wide
Web.

Preinstallation steps (all bays)

Before you install drives in the server, verify that you have
all the cables and other equipment specified in the
documentation that comes with the drive. You might also
need to perform certain preinstallation activities. Some of
the steps are required only during the initial installation of
an option.
1. Read "Safety information" on page 125 and the
documentation that comes with your drive.
2. Choose the bay in which you want to install the drive.
3. Check the instructions that come with the drive to see
if you need to set any switches or jumpers on the
drive. If you are installing a SCSI device, be sure to set
the SCSI ID for that device.

Installing a drive in bay 2 or 4

Note: The EMI integrity and cooling of the server are both
protected by having the bays covered or occupied.
When you install a drive, save the filler panel and
EMC shield from the bay, in case you later remove
the drive and do not replace it with another.
56
Hardware Maintenance Manual: xSeries 200