Error Symptoms - IBM xSeries 200 Hardware Maintenance Manual

Hide thumbs Also See for xSeries 200:
Table of Contents

Advertisement

Error
Code/Symptom FRU/Action
301-XXX-000
(Failed
Keyboard test)
405-XXX-000
(Failed Ethernet
test on controller
on the System
Board)
405-XXX-00N
(Failed Ethernet
test on adapter
in PCI slot N)
415-XXX-000
(Failed Modem
test)

Error symptoms

General
CD is not
working
properly.
CD-ROM drive
tray is not
working. (The
server must be
powered-on.)
CD-ROM drive
is not
recognized.
Power switch
does not work.
CD-ROM drive
cable is not
plugged in.
1. Keyboard
1. Verify that Ethernet is not disabled in
BIOS.
2. System Board
1. Adapter in PCI slot N.
2. System Board
1. Cable
2. Modem
3. System Board
FRU/Action
1. Clean the CD.
2. Run CD-ROM diagnostics.
3. CD-ROM Drive
1. Insert the end of a paper clip into the
manual tray-release opening.
2. Run CD-ROM diagnostics.
3. CD-ROM Drive
1. Run Configuration/Setup, enable primary
IDE channel.
2. Check cables and jumpers.
3. Check for correct device driver.
4. Run CD-ROM diagnostics.
5. CD-ROM drive
6. System Board
1. Verify that switch number 5 of switch
block is Off.
2. Power Switch Assembly
3. System Board
1. Make sure CD-ROM drive cable is plugged
in.
Chapter 7. Symptom-to-FRU index