Installing Internal Drives; Internal Drive Bays - IBM xSeries 200 Hardware Maintenance Manual

Hide thumbs Also See for xSeries 200:
Table of Contents

Advertisement

board. See "System board internal cable connectors"
on page 42 for the location of this connector.
Note: If you are installing a ServeRAID adapter and
already have a SCSI adapter installed, remove
the SCSI adapter and store it for future use.
4. If you have other adapters or options to install or
remove, do so now.
5. Rotate the front adapter support bracket to the closed
(locked) position.
6. Reinstall the rear adapter retaining bracket; then, rotate
the bracket to the closed (locked) position.
7. Reinstall the side cover, see "Installing the cover" on
page 70 for details.
8. Reconnect the external cables and power cords; then,
turn on the peripheral devices and the server.

Installing internal drives

Different types of drives enable your server to read
multiple types of media and store data in different formats.
Depending on your server model, you might have one or
more of the following drives installed.
v Diskette
v Hard disk
v CD-ROM
v Tape

Internal drive bays

Your server comes with an IDE CD-ROM drive installed in
bay 1, a 3.5-in., 1.44 MB diskette drive in bay 3, and a
hard disk drive in bay 5. For instructions on installing
drives in bays 1 and 3, see "CD-ROM drive" on page 90
and "Floppy disk drive" on page 91.
Note: The illustrations in this document might differ slightly
from your hardware.
54
Hardware Maintenance Manual: xSeries 200

Advertisement

Table of Contents
loading

Table of Contents