Error
Code/Symptom FRU/Action
035-XXX-S99
(Failed RAID
test on PCI slot
S. S = number
of failing PCI
slot. Check
System Error
Log before
replacing a
FRU.)
035-XXX-SNN
(Check System
Error Log before
replacing a
FRU. S =
number of failing
PCI slot; NN =
SCSI ID of
failing fixed
disk.)
035-253-S99
(RAID adapter
initialization
failure)
075-XXX-000
(Failed Power
Supply test)
089-XXX-001
(Failed
Microprocessor
test)
089-XXX-002
(Failed Optional
Microprocessor
test)
180-XXX-003
(Failed System
Board LED test)
201-XXX-0NN
(Failed Memory
test, see
"Memory
Settings" on
page 36.) NN =
DIMM location.
201-XXX-999
(Multiple DIMM
failure, see error
text.)
202-XXX-001
(Failed System
Cache test)
1. Adapter
2. SCSI Backplane
3. Cable
1. Fixed Disk with SCSI ID NN on RAID
adapter in PCI slot S.
1. ServeRAID Adapter in slot S is not
configured properly. Obtain the basic and
extended configuration status and refer to
the ServeRAID Hardware Maintenance
Manual for more information.
2. Cable
3. Adapter
1. Power Supply
1. Microprocessor
1. Optional Microprocessor 2
1. System Board
1. DIMM Location J1-J4
2. Memory card
1. See error text for failing DIMMs
1. Microprocessor CPU 1
Chapter 7. Symptom-to-FRU index