6
?
7
ENTER
Press the > key. Each time the
item and current setting change as shown below.
>Baud rate
9600
>Data bits
8
>Stop bits
1
>Parity
None
>Protocol
DTR(pos.)&XON
>Barcode Mode

Off

Display the setting item to be changed and press the ENTER key. The
message display indicates a question mark (?). The following
example explains how to change the Baud rate. The settings for
other items can be changed in the same manner.
>Baud rate
?
9600
1-43
Operating the Operator Panel
key is pressed, the setting
or
Definable baud rates: 1200, 2400, 4800,
9600 (default), 19200, 38400, 57600,
115200
Definable data bits: 7, 8 (default)
Definable stop bits: 1 (default), 2
Definable parity: None (default), Odd,
Even, Ignore
Definable protocol: DTR (pos.) & XON
(default), DTP (positive), DTR
(negative), XON/XOFF, ETX/ACK
If set to On when the option barcode
reader is installed, the mode of the
serial interface will be the barcode
mode.