Layout - Kemppi FastMig MXP 37 Pipe Steel Operating Manual

Hide thumbs Also See for FastMig MXP 37 Pipe Steel:
Table of Contents

Advertisement

3.2

Layout

10.
CH REMOTE
CHANNEL
5. 6.
1.
ON/OFF button
2.
Activates MIG welding dynamics (short press)
Selects the active wire feeder, if several wire feeders exist (long press)
3.
Gas test
4.
Wire inch
5.
Selects the previous memory channel
6.
Selects the next memory channel (short press)
Locks selected memory channel (long press)
7.
Selects welding gun trigger mode (short press) or turns MatchLog function ON/OFF
8.
Selects crater fill, hot start (short press) or MMA/CC/CV (long press)
9.
Selects panel control, gun control unit or hand-held control unit (short press).
Turns memory channel remote selection ON/OFF (long press).
10. Power control knob
11. Arc length and voltage control knob.
Automatic weld data display
Last recorded welding values are displayed post welding.
Voltage display
Voltage display will show arc voltage if selected from the setup panel. Voltage display's last
dot indicates that arc voltage display is selected (for example 23.5. V). If arc voltage feature is
not used, pole voltage of the power source is shown.
© Kemppi Oy / 1515
1.
2.
3.
4T
2T
7.
4.
11.
PANEL
XF 37
8.
9.
EN
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fastmig mxp 38

Table of Contents