Control Card A001 Layout; Control Card A001 Jumper - Kemppi WeldForce KPS 3500 Service Manual

Hide thumbs Also See for WeldForce KPS 3500:
Table of Contents

Advertisement

Control card A001 layout

X10
X11
X12
X1
H1
X7
5 6 7
X2
H5
R164
H6
H7
H8
Control card A001 jumper functions
5
6
7
Factory setting
X7
MIG, wire feeder is other
1
than KWF
2
Scratch-TIG enabled
OCV approx.. + 16 V
3
(VRD)
4
Not in use
5
Factory setting
If the arc is not lit in 2
6
seconds, the inverter is
stopped.(MIG)
7
Factory setting
H2
H3
H4
X13
X14
X23
R164 Inverter frequency
X21
X20
1
2
3
4
5
6
MIG, wire feeder is KWF
Scratch-TIG disabled
OCV is approx. + 65 V
Factory setting
Not in use
If the arc is not lit in 2 seconds, the inverter &
wire feeding are stopped.(MIG)
Not in use
7
11