3.5

Arc voltage display

FastMig X is capable of measuring and showing the voltage close to the welding arc. By taking
this feature into use you don't need to be concerned about the voltage losses in welding
cables anymore. With this feature you are only required to set the voltage for the arc before
welding and after welding you can see the voltage close to the arc.
In order to use the arc voltage feature, follow these steps:
1.
After setting up the welding equipment for the first time, connect the voltage sensing
cable to the welding piece and the measurement cable between the wire feeder and the
power source.
2.
If you are using a sub-feeder, enter the length of the sub-feeder to the SubFeederLength
parameter.
3.
Set the welding parameters according to your application. Note that the set voltage
when using 1-MIG, MIG and WiseThin+ welding processes means always the voltage in
the arc despite of ArcVoltage setting.
4.
Weld with 1-MIG, MIG or with Pulse MIG for at least 5 seconds. During that time the
welding machine calibrates itself for the welding cable length in question. Calibration
values are stored into the welding machine, therefore this calibration is required only
once after installing the welding machine package.
5.
If you want to see arc voltage in panels during and after welding, turn the ArcVoltage
setting to ON in X 37 setup panel. Dot after voltage value in XF 37 or XF 38 panel means
that showed value is arc voltage. In the weld data after welding in X 37 panel 'AVol'
means also the arc voltage.
6.
Voltage sensing cable can be removed after the calibration procedure, but it is
recommended to use it always.
Steps 1-3 should be repeated every time, when the length of the welding or grounding cable
NOTE!
is changed.
20
FastMig MXP 37 Pipe, MXP 38
Material
Wire ø (mm) Shielding gas
AlMg5
1.2
AlSi5
1.2
Fe
1.0
Fe
1.2
CrNiMo 19 12
1.0
CrNiMo 19 12
1.2
AlMg5
1.2
AlSi5
1.2
Fe
0.9
Fe
1.0
Fe
1.2
Fe
0.9
Fe
1.0
Fe
1.2
Fe Metal
1.2
Fe Metal
1.2
Fe Rutil
1.2
Fe Rutil
1.2
CrNiMo 19 12
1.0
CrNiMo 19 12
1.2
FC-CrNiMo 19 12
1.2
Process
Ar
Pulse/Double Pulse
Ar
Pulse/Double Pulse
Ar+15–25%CO₂
Pulse/Double Pulse
Ar+15–25%CO₂
Pulse/Double Pulse
Ar+2%CO₂
Pulse/Double Pulse
Ar+2%CO₂
Pulse/Double Pulse
Ar
1-MIG
Ar
1-MIG
Ar+15–25%CO₂
1-MIG
Ar+15–25%CO₂
1-MIG
Ar+15–25%CO₂
1-MIG
CO₂
1-MIG
CO₂
1-MIG
CO₂
1-MIG
Ar+15–25%CO₂
1-MIG
CO₂
1-MIG
Ar+15–25%CO₂
1-MIG
CO₂
1-MIG
Ar+2%CO₂
1-MIG
Ar+2%CO₂
1-MIG
Ar+15–25%CO₂
1-MIG
Number
A02
A12
F03
F04
S06
S04
A02
A12
F02
F03
F04
F22
F23
F24
M04
M24
R04
R14
S03
S04
S84

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fastmig mxp 38

Table of Contents