THOMSON ViBE VS7000 User Manual page 110

Convergent video system
Table of Contents

Advertisement

Chapter 3 'Web Browser Interface' — Workflow Library Content Parameters
110
Figure 3-79. TS over IP input parameters
For this item, you must set the following parameters:
IP
address: set the IP and LAN parameters. If it is a unicast address, it
must be part of a local network and must be consistent with the IP
configuration of the ViBE VS7000.
UDP
port: enter the port used to get the stream.
Synchro loss
threshold: set the number of milliseconds after which the
absence of signal in input is considered a loss of synchronization.
Maximum TS
bitrate: enter the maximum bit rate of the transport
stream, in bits per second. Be sure to set a correct value as the system
will use it to decide which node will be able to manage this input.
Define backup
input: set to true if you want to define a backup input
for this input. In that case, enter values in the
and
Backup input UDP port
TS File Input
The
TS file input
item supports only CBR transport streams (i.e. with
stuffing packets).
Figure 3-80. TS file input parameters
For this item, you must set the following parameters:
Backup input IP address
fields.
ViBE VS7000
User Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents