THOMSON ViBE VS7000 User Manual page 108

Convergent video system
Table of Contents

Advertisement

Chapter 3 'Web Browser Interface' — Workflow Library Content Parameters
108
The two parameters must be of the same type.
The two parameters must have the same restrictions (for example,
have the same length or the same range).
The parameter toward which the link will be made must be public, or
private with a label defined.
Example: lets us consider a workflow that contains 2 TS over IP inputs,
and we want to set the synchro loss threshold to the same value in both
inputs. In this case, we can set the value in the first input item, and insert
a link from the second input to the first one.
To use the link tool, proceed as follows:
1.
Open an item. In our example, open the second TS over IP input item.
2.
Select the parameter for which you wish to make a link to another
parameter. In our example, the Synchro loss threshold.
3.
Click the
button located in the top-right corner.
Figure 3-76. Setting a link to another parameter
4.
Select the parameter that should be used. In our example, select the
synchro loss threshold of the first TS over IP input item.
Figure 3-77. Selecting the parameter to link with