INSTALLATION PRECAUTIONS

A Firewall is a central device in your network, therefore do not neglect it – install it in the best way possible,
under the best conditions.
NOTE
Instructions on how to connect products are also given in the Poster Quick Installation Guide provided
with the Firewall.

Conditions of use

The Stormshield Network Firewall has been designed to run continuously, in an office or in a server room.
If you wish to install your appliance in an office, choose a flat and uncluttered surface. Add the non-slip rubber
feet to SN500, SN700, SN900 and SN910 models: stick a non-slip rubber foot to the underside of the
appliance, close to each corner about 2 cm from the edges. This will ensure the stability of the Firewall and
protect it from scratches.
WARNING
The Firewall has to be installed in compliance with the state of the art corresponding to the practical
terms of secure installation, namely: in a protected office or other premises with limited access. In
order to guarantee the integrity of the product and to avoid compromising the security of your
installation, all unauthorized access to the Firewall has to be avoided.
NOTE
Ensure that the cables do not obstruct passageways to prevent them from being pulled out or the
product from falling.
Your Stormshield Firewall is intended for indoor use (office environment or other IT environment), away from
areas that may receive rainfall, floods or excessive humidity. It must be installed away from sources of
shocks, vibrations, and dust, in an environment where the temperature conforms to the product's
specifications. The ideal room temperature is around 25°C.
The tables below set out the operational temperature, storage temperature and humidity level for all models
of SN range.
SN150, SN200, SN300, SN500, SN700, SN900, SN910, SN2000 and SN3000 models:
Operating
temperature
5° to 40°C
(41° to 104°F)
SN6000 model:
Operating
temperature
10° to 35°C
(50° to 95°F)
Avoid in particular direct exposure to sunlight. Always keep an adequate distance around the
appliance's vents in order to guarantee a free flow of air, thereby preventing the possibility of
overheating.
Page 30 /59
Relative humidity,
operating (%)
20% to 90% at 40°C (104°F)
without condensation
Relative humidity,
operating (%)
8% to 90%
without condensation
IMPORTANT
PRESENTATION AND INSTALLATION GUIDE – SN RANGE
Storage
Relative humidity, storage (%)
temperature
-30° to 65°C
5% to 95% at 60°C (140°F)
(-22° to 149°F)
Storage
Relative humidity, storage (%)
temperature
-30° to 65°C
5% to 95% at 60°C (140°F)
(-22° to 149°F)
snengde_installation-product-SN-range v1.2 - Copyright Netasq 2015