TROUBLESHOOTING

TROUBLE
Control panel lights are not
illuminated.
Fold table stop not moving
when "Test"/ "Start" is
pressed.
"Cover Open" is displayed. Cover open
"Paper out " is displayed.
"Paper Jam" is displayed.
Black marks on the folded
paper.
Fold is skewed.
Stacker belts do not turn.
Documents are wrinkled or
crunched.
In-feed tray lever does not
work
Double feeding forms
Not feeding documents
Power loss
POSSIBLE CAUSE
No power at the wall outlet.
No power to the machine inlet.
No power to the control panel.
Internal electrical failure
Fold table is not plugged in.
Electrical or mechanical failure
Magnetic switch is broken.
In-feed tray is empty.
Paper misfeed
Paper jammed at exit of
pressure sealer
In-feed tires, separator, and/or
fold rollers are dirty.
In-feed tray is out of
adjustment.
Broken drive belt, worn drive
gear.
Fold tables are not inserted
correctly.
Piece of paper or other material
is stuck in the fold table.
Broken spring
Documents stuck together
More tension is needed
Feed tire or separator worn
Feed tire is dirty
Feed tire or separator worn
Circuit Breaker tripped
Under adverse conditions,
power input level may drop
below acceptable limits
REMEDY
Check wall outlet.
Check power cord for frayed/broken wires.
Press the button on the circuit breaker.
Call for service.
Plug in fold table.
Call for service.
Close cover.
Call for service.
Place documents on the in-feed tray.
Reload paper and press "Counter Reset"
button.
Remove paper and press "Counter Reset"
button. (See Fig. 16, page 20)
Clean the parts with approved roller cleaner
and rejuvenator.
Turn skew adjuster knob to remove the skew.
Call for service.
Remove and reinstall fold tables. Be sure
they're properly positioned.
Remove object from the fold table.
Call for service.
Jog forms to remove static electricity.
Adjust the infeed tension lever
Call for service
Clean feed tire
Call for Service
Press black reset button on back of machine.
When power is restored, turn off machine, then
turn on again to restore normal operations.