15
GRAND DINK 50
. ELECTRICAL EQUIPMENT
Starter Relay
STARTER RELAY INSPECTION
Remove the front cover.
Disconnect the starter relay coupler and
then remove the starter relay.
Yellow/Red
Red
Connect the starter relay green/yellow
terminal to the 12V battery positive (+)
terminal and the relay yellow/red terminal to
the battery negative (-) terminal. Check for
continuity between the starter relay red and
red/white terminals. The relay is normal if
there is continuity.
Red/White
Green/Yellow
STARTER MOTOR REMOVAL
Bolts
Disconnect the starter motor cable.
Remove the two bolts attaching the starter
motor and remove the starter motor.
The installation sequence is the reverse of
removal.
Starter Motor
15-12