START RELAY INSPECTION
Release the rubber cap (1) and remove the nut
(2), then disconnect the start motor cable.
Turn the ignition switch to "ON"position.
Squeeze and hold the brake lever fully then
push the starter switch.
The coil is normal if the start relay switch
clicks.
Release the rubber caps and remove the nuts,
then disconnect the start motor cable, battery
positive cable and harness wire.
Disconnect the start relay connector and then
remove start relay.
Connect a fully charged 12 V battery positive
wire to the relay switch Yellow/Red wire
terminal and negative wire to the
Green/Yellow wire terminal.
There should be continuity between the cable
terminals while the battery is connected, and
no continuity when the battery is
disconnected.