. ELECTRICAL EQUIPMENT

SERVICE INFORMATION

GENERAL INSTRUCTIONS
x It is not necessary to check the battery electrolyte or fill with distilled water.
x Remove the battery from the motorcycle for charging. Do not remove the electrolyte cap..
x Do not quick charge the battery. Quick charging should only be done in an emergency..
x Charge the battery according to the charging current and time specified on the battery.
x When charging, check the voltage (open voltage) with an electric tester.
x When replacing the battery, do not use a traditional battery.
SPECIFICATIONS

Battery

Spark plug
Spark plug gap
Ignition coil resistance
Pulser coil resistance (20 )
Ignition timing

TROUBLESHOOTING

CHARGING SYSTEM

No power
x Dead battery
x Disconnected battery cable
x Fuse burned out
x Faulty ignition switch
Low power
x Weak battery
x Loose battery connection
x Charging system failure
x Faulty regulator/rectifier
15-1
Capacity
Voltage
Charging
Standard
current
Quick
(NGK)
Primary coil
Secondary coil
(with plug cap)
Secondary coil
(without plug cap)
GRANK DINK 50
13.0 13.2V
BR8HSA
0.6 0.7mm
0.2 0.3:
7.0 8.4K:
2.5 3.2K:
80 160:
13.5qr1qBTDC/2000rpm
Intermittent power
x Loose battery cable connection
x Loose charging system connection
x Loose connection or short circuit in ignition system
x Loose connection or short circuit in lighting system
Charging system failure
x Loose, broken or shorted wire or connector
x Faulty regulator/rectifier
x Faulty A.C. generator