OmniSwitch Backup Power Shelf/System (BPS)

Power Supply Redundancy

Power supplies installed in the same OS-BPS chassis may operate in a redundant or backup configuration
by sharing the same electrical load with another power supply.

Hot Swapping OS-BPS Power Supplies

OS-BPS power supplies are hot swappable. If redundant power supplies are operating in the chassis, a
power supply can be removed or replaced without adversely affecting normal operation. New power
supplies may be inserted in empty power supply slots at any time.

Considerations if OS-BPS is the Only Power Source In a Virtual Chassis

If the primary power supply fails on any switch connected to the OS-BPS, leaving the OS-BPS as the
switch's only power source, it is recommended that the primary power supply is replaced on the switch as
soon as possible.

Chassis Status LEDs

The chassis provides a series of status LEDs located on the front panel. These LEDs offer basic status
information for hardware operation and port link and activity status.
LED
OK
C1 - C8
ECO LED
OmniSwitch 6860 Hardware Users Guide
State
Solid Green
Blinking Amber
Solid Green
Solid Amber
Solid Green
May 2014
Description
Operational
In transitional state (e.g. performing
diagnostics or booting)
Both power supplies are functional
One power supply is functional
Power save mode is currently active

Chassis Status LEDs