Dell PowerConnect 8024 User Configuration Manual page 168

Hide thumbs Also See for PowerConnect 8024:
Table of Contents

Advertisement

At this point, if Unit 2 is powered off or rebooted due to an unexpected
failure, show switch gives the following output:
console#show switch
SW
Management
Status
--- ---------
1
Stack Member
2
Unassigned
3
Mgmt Switch
4
Stack Member
When the failed unit resumes normal operation, the previous configuration
that exists for that unit is reapplied by the stack master.
To permanently remove the unit from the stack, enter into Stack Config
Mode and use the member command, as the following example shows.
console#configure
console(config)#stack
console(config-stack)#no member 2
console(config-stack)#exit
console(config)#exit
console#show switch
SW
Management
Status
--- ---------
1
Stack Member
3
Mgmt Switch
4
Stack Member
168
Managing a Switch Stack
Standby
Preconfig
Status
Model ID
------- --------
PC8024
PC8024
PC8024
PC8024F
Standby
Preconfig
Status
Model ID
------- --------
PC8024
PC8024
PC8024F
Plugged-
Switch
in Model
Status
ID
-------------------
PC8024
OK
Not Present 0.0.0.0
PC8024
OK
PC8024F
OK
Plugged-
Switch
in Model
Status
ID
-------------------
PC8024
OK
PC8024
OK
PC8024F
OK
Code
Version
--------
9.19.0.2
9.19.0.2
9.19.0.2
Code
Version
--------
9.19.0.2
9.19.0.2
9.19.0.2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents