6. Setup Before Departure
6.9

Resetting Distance and Trip Counters

Record menu
To reset the distance and trip counters to zero, do the following:
1. Spin the scrollwheel to show Menu/Info/Chart Menu in the mouse functions area then push the left mouse
button.
2. Choose Record then push the scrollwheel.
3. Choose Reset then push the scrollwheel.
4. Choose Distance Counter or Trip Counter as appropriate then push the scrollwheel.
Distance counter: Reset both Distance and Trip counters.
Trip counter: Reset Trip counter.
5. An appropriate prompts asks you if you are sure to reset chosen counter. Click the OK button to reset. The
prompt window disappears.
6.10

Verifying Datum

Datum is used to choose between different models of the earth. It is essential that you use datum in a consistent way.
If you use paper charts together with electronic chart material, it is recommended that you use the same datum as
your current paper chart to avoid misalignment between your electronic chart system and points taken or plotted on
your current paper chart.
Once you have chosen a datum, all
numerical latitude-longitude
position values are presented in
your chosen datum.
To change the datum:
1. Choose the datum indication in
the top box in the information
area.
2. Spin the scrollwheel to choose
appropriate datum, the one that
matches your paper charts, then
push the scrollwheel.
Note: ARCS raster charts contain some rasterized position information, like scale bars on PA paper charts, which is
true only if you have chosen native datum of that ARCS chart.