1. Introduction
1.2

System Configuration

The ECDIS EC1000C Workstation, comprised of the components shown in the illustration below, displays
electronic sea charts and operates as the operator interface for the system.
The ECDIS processor is connected to various sensors, and performs navigation calculations and route monitoring.
Connections to interfaces are typically made with a LAN (Local Area Network) Adapter.
The ECDIS processor can be used for both route planning and route monitoring. If required, there can be additional
identical ECDIS EC1000C Workstation(s) connected to the same LAN to share the tasks of the ECDIS. If the
system incorporates more than one ECDIS EC1000C Workstation, one or more workstation(s) can be used as an
operator interface (with "full" usage rights) and one or more workstation(s) may be used as planning stations (usage
rights as "planning").
If the system has two workstations connected together as multiple workstations, the system keeps data on the
workstations harmonised and also tracks selections and settings made on any workstation.
Typically there can be the following kinds of configurations of workstations:
Mode as Single, only one workstation is used in the system.
Mode as Multiple, two workstations are used in the system where usage rights and sensor source of
workstations can be changed by the operator.
For more information, see Chapter 18 Common Reference System.
1.2.1

Single workstation

ECDIS Monitor
MU-201CE
(FEA-2107)
or
100-230 VAC
MU-231CE
(FEA-2807)
CALCOMP
DRAWING-
BOARD III
DIGITIZER
ECDIS PROCESSOR
RADAR OVERLAY PCB
100-230 VAC
FAR-2xx7
series radar
Category of Units: All units protected from weather
1-2
Conning Monitor
MU-201CE
or
MU-231CE
(WORKSTATION)
EC1000C
Control Unit
RCU-018
or
Control Unit
RCU-015
Remote Control Unit
RCU-016
Single workstation with connection to navigation sensors
100-230 VAC
LAN-ADAPTER
EC-1010
HUB-
LAN-ADAPTER
100
EC-1010
100-230 VAC
B-ADAPTER
EC-1020
24 VDC
Selector
PRINTER
(USB)
ARPA RADARS
POSITION-FIXING EQUIPMENT
TRACKPIL OT
LOG/DUAL AXIS LOG
AIS
GYROCOMPASS
24 VDC
POSITION-FIXING EQUIPMENT
ENGINE CONTROL
ECHOSOUNDER
WIND SENSOR
WATER TEMP. METER
AMWSS (Alarm Monitoring
Watch Safety System)
24 VDC
GYROCOMPASS
(SYNCHRO, STEPPER)
LOG (200P/NM)
ANALOG INPUT (8 CHANNELS)
ALARM OUTPUT
RADAR 1 (VIDEO, HL, AZ)
RADAR 2 (VIDEO, HL, AZ)
OPTION
EXTERNAL