C. Troubleshooting
Error
Description
code
2201
PFC start
failed
2501
PFC start
failed
2801
PFC start
failed
2202
LPS start
failed
2502
LPS start
failed
2802
LPS start
failed
2203
BOOST start
failed
2503
BOOST start
failed
2803
BOOST start
failed
2206
Lamp ignition
failed
2506
Lamp ignition
failed
2806
Lamp ignition
failed
2207
Lamp voltage
range
2507
Lamp voltage
range
2807
Lamp voltage
range
2208
Lamp power
range
2508
Lamp power
range
2808
Lamp power
range
4199
FIB reset
failed
5098
Flash full
5097
Flash
management
full
170
Error
Warn-
Caused by
ing
-
Yes
LPS (address 0x20)
-
Yes
LPS (address 0x22)
-
Yes
LPS (address 0x28)
-
Yes
LPS (address 0x20)
-
Yes
LPS (address 0x22)
-
Yes
LPS (address 0x28)
-
Yes
LPS (address 0x20)
-
Yes
LPS (address 0x22)
-
Yes
LPS (address 0x28)
-
Yes
hot restrike,
lamp with many strikes, maximum
run time exceeded
-
Yes
hot restrike,
lamp with many strikes, maximum
run time exceeded
-
Yes
hot restrike,
lamp with many strikes, maximum
run time exceeded
-
Yes
lamp voltage too high or too low
-
Yes
lamp voltage too high or too low
-
Yes
lamp voltage too high or too low
-
Yes
lamp voltage too high or too low
-
Yes
lamp voltage too high or too low
-
Yes
lamp voltage too high or too low
-
Yes
no communication with FIB
-
Yes
Internal Backup device has
reached its maximum capacity
-
Yes
Internal Backup device has
reached its maximum capacity
Action
Replace LPS
Replace LPS
Replace LPS
Replace LPS
Replace LPS
Replace LPS
Replace LPS
Replace LPS
Replace LPS
Let cool down the lamp for at least
3 minutes. Replace the lamp or
SPG with a new one If problem
persists, call a qualified service
engineer
Let cool down the lamp for at least
3 minutes. Replace the lamp or
SPG with a new one If problem
persists, call a qualified service
engineer
Let cool down the lamp for at least
3 minutes. Replace the lamp or
SPG with a new one If problem
persists, call a qualified service
engineer
Replace lamp
Replace lamp
Replace lamp
Replace lamp
Replace lamp
Replace lamp
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer