Flow Control And Task Processing - Radyne DMD2401 LB Installation And Operation Manual

L-band satellite modem and odu driver
Table of Contents

Advertisement

User Interfaces
DMD2401 LB/ST L-Band Satellite Modem and ODU Driver
When Radyne equipment is queried for information (Query Mod, Query Demod, etc.) it responds
by sending back two blocks of data; a non-volatile section (parameters that can be modified by
the user) and a volatile section (status information). It also returns a count value that indicates
how large the non-volatile section is. This count is used by M&C developers to index into the
start of the volatile section.
When new features are added to Radyne equipment, the control parameters are appended to the
end of the non-volatile section, and status of the features, if any, are added at the end of the
volatile section. If a remote M&C queries two pieces of Radyne equipment with different
software revisions, they might respond with two different sized packets. The remote M&C MUST
make use of the non-volatile count value to index to the start of the volatile section. If the
remote M&C is not aware of the newly added features to the Radyne product, it should disregard
the parameters at the end of the non-volatile section and index to the start of the volatile section.
If packets are handled in this fashion, there will also be backward-compatibility between Radyne
equipment and M&C systems. Remote M&C systems need not be modified every time a feature
is added unless the user needs access to that feature.

4.4.7 Flow Control and Task Processing

The original packet sender (the M&C computer) relies on accurate timeout information with
regard to each piece of equipment under its control. This provides for efficient bus
communication without unnecessary handshake overhead timing. One critical value is
designated the Inter-Frame Space (FS). The Inter-Frame Space provides a period of time in
which the packet receiver and medium (control bus and M&C computer interface) fully recover
from the packet transmission/reception process and the receiver is ready to accept a new
message. The programmed value of the Inter-Frame Space should be greater than the sum of
the "turnaround time" and the round-trip (sender/receiver/bus) propagation time, including
handshake overhead. The term "turnaround time" refers to the amount of time required for a
receiver to be re-enabled and ready to receive a packet after having just received a packet. In
flow control programming, the Inter-Frame Space may be determined empirically in accord with
the system configuration, or calculated based on established maximum equipment task
processing times.
Each piece of supported equipment on the control bus executes a Radyne Link Level Task
(RLLT) in accordance with its internal hardware and fixed program structure. In a flow control
example, the RLLT issues an internal "message in" system call to invoke an I/0 wait condition
that persists until the task receives a command from the M&C computer. The RLLT has the
option of setting a timeout on the incoming message. Thus, if the equipment does not receive
an information/command packet within a given time period, the associated RLLT exits the I/0
wait state and takes appropriate action.
Radyne equipment is logically linked to the control bus via an Internal I/O Processing Task
(IOPT) to handle frame sequencing, error checking, and handshaking. The IOPT is essentially a
link between the equipment RLLT and the control bus. Each time the M&C computer sends a
message packet, the IOPT receives the message and performs error checking. If errors are
absent, the IOPT passes the message to the equipment's RLLT. If the IOPT detects errors, it
appends error messages to the packet. Whenever an error occurs, the IOPT notes it and
discards the message; but it keeps track of the incoming packet. Once the packet is complete,
the IOPT conveys the appropriate message to the RLLT and invokes an I/0 wait state (wait for
next <SYN> character).
If the RLLT receives the packetized message from the sender before it times out, it checks for
any error messages appended by the IOPT. In the absence of errors, the RLLT processes the
received command sent via the transmitted packet and issues a "message out" system call to
ultimately acknowledge the received packet. This call generates the response packet conveyed
to the sender. If the IOPT sensed errors in the received packet and an RLLT timeout has not
4-36