Brother PD-3000 Instruction Manual page 163

Hide thumbs Also See for PD-3000:
Table of Contents

Advertisement

Example 2
Sequence 2 for stacker
This sequence ejects material immediately after the work clamp rises on completion of sewing, and programs stacking
operation.
Option output 3
Option output 4
Option output 5
Option output 6
Timing chart
Trigger code detection
during sewing
Movement of sewing start
point after sewing ends
Program setting values
Output
Operation
No.
setting
Condition
ON
3
OFF
ON
4
OFF
ON
5
OFF
6
ON
UP/DW: Rising/lowering for removing material
MOVE: Movement for removing material
BAR1: For holding material
BAR2: For moving material
0.2 sec.
Clamp rising sensor
(option output 1) ON
Output condition
Timer 1
[ms]
Content
No.
Movement of
2
sewing start
0
point
78
Output 5 ON
200
Trigger
14
0
detection
40
Input 1 ON
0
42
Input 2 ON
0
78
Output 6 OFF
10
75
Output 3 OFF
10
CHAPTER 5 EXTENDED OPTION OUTPUT
10ms
0.5 sec.
Stacker sensor
(option output 2) ON
Enabling conditions
Timer 2
[ms]
Condition
No.
0
6
End of sewing
0
0
0
0
0
500
PD-3000
10ms
Disabling conditions
Condition
Content
Content
No.
Sewing
machine
1
returns to home
position
155

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents