Formulation - Sartorius FC06BBE-S Operating Instructions Manual

Factory series fc and fcg models electronic precision scales
Hide thumbs Also See for FC06BBE-S:
Table of Contents

Advertisement

Formulation

M
Purpose
With this application program you
can add weight values and calculated
values to a totalization memory as
components of a formula.
You can use the "Formulation"
application in combination with
a program chosen from Application 1
(except Recalculation) and one from
Application 2 (checkweighing, time-
controlled functions) as well as with
the extra functions.
Available Features
– Totalization of weight values and
calculated values
– Weigh in different components to
a total amount defined by pressing the
Nom
soft key and entering the value
through the numeric keys
– Simultaneous storage of net and
calculated values
– Optional configuration in the Setup
menu for loading weight values and
calculated values either from Applica-
tion 1 (e.g., counting, weighing in
percent) or from Application 2 (check-
weighing, time-controlled functions)
– Totalization memory for up to 65535
values
– Transaction counter and current total
displayed in the text line
– Scale tared after a value is stored
– Manual input of the number of
individual weighing operations (target
nDef
no. of operation
). Result printed
and memory cleared after printout of
nDef
.
– Optional configuration in the Setup
menu to add the current weight, with
display accuracy, to the current total by
M+
pressing the
soft key and generat-
ing a printout of the result
– Optional configuration in the Setup
menu for stability-dependent storage
Stability
of the measured value:
range
– Optional automatic storage of meas-
ured values
Storage of measured value is indicated
by
.
Uu
indicates that you can place a load
zz
on the scale.
– Minimum load threshold for automatic
storage
M-
– Press the
soft key to delete the last
value added to the totalization memory.
The transaction counter value is reduced
by one and a printout is generated.
– Printout of an evaluation of results,
depending on the Application 1 or
Application 2 parameters. Configure the
Setup menu to define the information
included on this printout.
MR
– Press the key identified by
key) for a printout of an intermediate
evaluation after each addition or a final
evaluation
– A final evaluation is printed when
the formulation routine is ended by
pressing c, if no final evaluation was
generated by pressing MR
– Optional configuration in the Setup
menu to clear the totalization memory
and reset the transaction counter by
pressing c or after an evaluation
is printed out
– Totalization data and transaction
counter data are stored in non-volatile
memory
– Continue formulation after turning the
scale off and back on
Factory Settings
Automatic storage:
Minimum load for automatic storage:
20 digits
Source of data for auto storage:
Application 1
Evaluated values:
Evaluation mode, MR key function:
Intermediate evalua-
tion, print
Printout of individual components:
Scale functions: Stability range:
2 digits
(soft
Printout: Application-defined output:
Print on request, then tare:
Soft Key Functions
M+
Add weight values or application
values to the total in the totali-
zation memory. The component
or transaction counter value
increases by one each time you
press this key.
M-
Delete the last value added to
memory. The transaction counter
value decreases by 1. You cannot
delete previous values by repeat-
edly pressing this key.
MR
Print or display an intermediate
or final evaluation
nDef
Store the input number of
components
Nom
Press to enter target component
weight using the numeric keys
Printout of Formulation Report
When an intermediate or final evaluation
is printed out, all results up to this point
are included.
Comp2 + 42.38 g
Tot.cp+184.89 g
Comp2: Weight of the 2nd component
Tot.cp: Total of all components
Off
Net
On
Off
83

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents