Status Buffer Messages
Appendix B
Status Buffer messages provide information about call progress, ISDN
link status, and error conditions. The Status Buffer contains only the
last 20 status messages, with relevant status items, generated during
unit operation. The most recent status message appears as 1, with the
remaining status messages appearing in descending order. Messages
shown entirely in capital letters are generated by the ISDN network.
Messages with lower case letters are generated by the Express 3100.
2047 BERT orig
Test remote originated 2047 BERT (bit error rate test) pattern.
2047 loopbk ansr
Test remote answered 2047 BERT pattern.
Answer
The Express 3100 answered a call on either the first or second
channel. The calling phone number is displayed if available.
ACCESS_INFO_DISCARDED
The network was unable to deliver access information to the
far end.
Back to online
Express 3100 went back online.
Bad async BPS
The Bonding protocol determined that the selected asynchro-
nous bit rate is not supported.
Bad AT numeric
User issued an AT command with an argument that was out
of range.