EFI-based SELViewer task

The EFI based SEL Viewer task is available on the System Maintenance Utility
(SMU). This task will not be available when running the Remote version. The EFI
SEL Viewer provides support for the user to perform the following:
v Examine all SEL entries stored in the non-volatile storage area of the server in
v Examine previously stored SEL entries from a file in text form or in hexadecimal.
v Save the SEL entries to a file.
v Clear the SEL entries from the non-volatile storage area.
v Sort the SEL records by various fields such as timestamp, sensor type number,
v Five columns of SEL data can be viewed from the EFI SEL Viewer Utility:

xSeries 382 SEL data tables

The following tables contain information on the data provided by the SEL Viewer
utility.
text form or in hexadecimal.
event description, and generator ID.
– Number of Event
– Time Stamp
– Sensor Type and Number
– Event Description
– Generator ID
Table 2. xSeries 382 generator ID codes
Generator ID
20 00
C0 00
0x31 00 -0x3F 00
Table 3. Sensor types, numbers and names
Sensor Type
01 (temperature)
01 (temperature)
01 (temperature)
01 (temperature)
01 (temperature)
01 (temperature)
01 (temperature)
01 (temperature)
01 (temperature)
02 (voltage)
02 (voltage)
02 (voltage)
02 (voltage)
System BIOS or System SW
Sensor Number
Sensor Name
20h
Memory board temperature
21H
Memory board SNC temperature
22h
PCI riser SIOH temperature
23h
Peripheral board AMB temperature
24h
PCI riser board temperature
25h
CPU area temperature
26h
Memory area temperature
81hp
Microprocessor 1temperature
82hp
Microprocessor 2 temperature
10h
System board +1.25V
11h
System board +1.5V
12h
System board +1.8V
13h
System board +3.3V
Generator
BMC
HSC
23