Thermosensor Inspection; Clutch Switch - Honda CBR150R Manual

Hide thumbs Also See for CBR150R:
Table of Contents

Advertisement

LIGHTS/METERS/SWITCHES
THERMOSENSOR INSPECTION
Keep flammable materials away from the electric heat-
ing element. Wear protective clothing, insulated gloves
and eye protection.
Drain the coolant (page 6-51.
Disconnect the thermosensor connector and remove the
thermosensor.
Suspend the thermosensor in a pan of coolant (50
-
50
mixture) on an electric heating element and measure the
resistance through the sensor as the coolant heats up:
NOTE:
Soak the thermosensor in coolant up to its threads with
at least 40 m m (1.57 in) from the bottom of the sensor.
Keep temperature constant for 3 minutes before test-
ing. A sudden change of temperature will result in in-
correct readings. Do not let the thermometer or
thermosensor touch the pan.
Temperature
I
50 "C (122 "F)
I
120
"C
(248 "F)
Resistance
133.9- 1 7 a . 9 ~
14.9- 1 7 . 3 ~
Replace the sensor if
it
is out of specifications by more
than 10 % at any temperature listed.
Install the thermosensor.
Apply sealant to the thermosensor threads. Do not apply
sealant to the sensor head.
Connect the thermosesor connector.
Fill and bleed the cooling system (page 6-5).
CLUTCH SWITCH
Disconnect the clutch switch connectors and check for
continuity.
There should be continuity with the clutch lever applied
and no continuity with it released.
THERMOMETER
\ A
THERMOSENSOR
20-16