Tunnel – Packing
Mode Page
Settings
Mode
Timeout
Threshold
Send Character
Trailing Character
Tunnel – Modem Emulation Page
A tunnel in connect mode can be initiated using modem commands incoming from the
serial line. If you click Modem Emulation at the top of one of the Tunnel pages, the
Tunnel – Modem Emulation page displays. Here you can select modem emulation
settings for the tunnel selected at the top of the page. For more information about modem
emulation, see
EDS Device Servers User Guide
Tunnel – Packing Mode Page
Description
Select the method used to pack data. Choices are:
Disabled = data is never packed. (default)
Timeout = data is sent after the timeout elapses.
Send Character = data is sent when the send character is read on
the serial line.
Enter the maximum number of milliseconds to wait before sending
queued data across the network. Default is 1000 milliseconds.
Enter the queued data limit that, when reached, immediately sends
queued data to the network. Default is 512 bytes.
Enter the send character. When this character is read on the serial
line, it forces the queued data to be sent immediately. Default is
<none>.
Enter the trailing character. This character is inserted into the
outgoing data stream immediately after the send character. Default is
<none>.
Modem Emulation
on page 147.