Required Adjustment Tools - Epson WorkForce 1100 Service Manual

Color inkjet printer
Hide thumbs Also See for WorkForce 1100:
Table of Contents

Advertisement

WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100

5.1.3 Required Adjustment Tools

The following table lists the adjustment tools required for adjustment of this product.
Table 5-5. List of Tools
No.
Name
Part Code
Adjustment
1
Program
G-26
2
1080614
G-45
3
1033657
G-71
4
1304682
PG Adjustment
5
1276333
Gauge
PF Tension
6
1294120
Measuring Tool
PF Roller Shaft
7
1304993
Position
Adjustment Jig
Adjustment
Category
Overview
This adjustment program is
Software
designed to display the required
adjustment items in the
appropriate order when a
replacement part is selected, and
provides workers with the
accurate adjustment order.
For the Parallelism Adjust
Grease
Bushing, Lower Paper Guide,
Driven Release Shaft, etc.
For the PF Roller, Front Paper
Grease
Guide, Rear Paper Guide and
etc.
For the Carriage Unit and
Grease
Carriage Shaft.
A gauge exclusively used to
Gauge
make PG Adjustment. Check
the correction value by
energizing it in the same way as
for Stylus Photo R1800.
Used to check whether or not
Measuring
the tension of the PF Drive Belt
tool
is within the specified value. If
load is greater than the specified
value, the PF Motor may
generate heat, burning off the
coil. Reversely, if load is less
than the specified value, the
paper feed position may shift.
Used to check whether or not
Adjusting
the deflection amount of the PF
jig
Roller Shaft is within the
specified value. Adjustment
values are confirmed in a pair
with the level block.
Adjustment Items and Overview
Table 5-5. List of Tools
No.
Name
Part Code
Level Block
8
1304994
Spanner (M3)
9
Commercially
available
Revision C
Category
Overview
Used to check whether or not
Adjusting
deflection amount of the PF
jig
Roller Shaft is within the
specified value. Adjustment
values are confirmed in a pair
with the PF Roller Shaft
Position Adjustment Jig.
Used to loosen the screw that
Tool
secures the Center Support
Bushing when performing PF
Roller Shaft Center Support
Position Adjustment.