WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100
Occurrence
Phenomenon Detail
Timing
At power-on
At power-on, the CR Motor does
not operate at all.
Troubleshooting
Table 3-11. Troubleshooting of Fatal Error
Faulty Part/
Part Name
CR Motor
1. Check the CR Motor connector cable for damages.
2. Check if the CR Motor operates normally.
3. Check that the CR Motor connector cable is connected to the
Main Board connector CN115.
Overview
Check Point
CN115
Revision C
Remedy
1. Replace the CR Motor with a new one.
2. Replace the CR Motor with a new one.
3. Connect the CR Motor connector cable to the
Main Board connector CN115.
Confidential
41