5.3.2 PG Adjustment

Some pictures used in this section are Stylus Photo R1800. The
C H E C K
adjustment method for WorkForce 1100/Epson Stylus Office
P O I N T
T1110/B1100/T1100/Epson ME Office 1100 is the same as the
one for Stylus Photo R1800.
When only removing the Carriage Shaft, you do not need to
perform this adjustment. In that case, mark the position of the
rib on the Parallelism Adjust Bushing (Left/Right) before
removing them, and make sure to align the markings with the
ribs when installing them.
Carriage Unit (p88).)
When any of the following parts has been removed or replaced, this adjustment must
be performed to secure the specified clearance between the print surface of the Print
Head and paper.
Print Head
PF Roller Shaft
Carriage Unit
Carriage Shaft (Including the case when just moved the Parallelism Adjust
Bushing)
Printer Mechanism
In this adjustment, use the same Adjustment Gauge on the left and right sides.
Figure 5-10. Adjustment Gauge
Do not touch the Adjustment Gauge Plate surface with bare
C A U T I O N
hands.
If the Adjustment Gauge Plate surface is stained by ink or, etc
wipe it with a soft cloth.
Adjustment
(Refer to 4.4.5 Carriage Shaft /
Adjustment Gauge
Continuity
Plate (Top face)
Measuring Point
Adjustment without Using Adjustment Program
5.3.2.1 PG Adjustment Method
Before starting PG adjustment, completely wipe drops of ink
C A U T I O N
around the Print Head. Remaining drops of ink will stick to the
continuity measurement portion of the Adjustment Gauge, and
generate continuity before the continuity measurement portion
makes contact with the metal frame around the Print Head,
interrupting accurate PG Adjustment.
As the ink in the Print Head may stick fast and damage the
Print Head during PG Adjustment, make the continuity time
detected with a tester as short as possible. (Maximum 3
minutes)
1.
Install the printer on a level base.
Place the printer on a level, warp-free table. Normal PG
C A U T I O N
Adjustment cannot be performed on a warped table.
2.
Connect the Tester to the printer frame and Adjustment Gauge.
Tester
Figure 5-11. Connecting the Tester
Revision C
Frame
Adjustment Gauge