DAF 95XF Maintenance Manual page 72

Hide thumbs Also See for 95XF:
Table of Contents

Advertisement

EXPLANATORY NOTES ON THE MAINTENANCE ACTIVITIES
Inspection and adjustment
Adjusting the unit-injector
1.
Slacken the lock nut of the adjusting bolt.
2.
Turn the adjusting bolt three to four times
clockwise and anti-clockwise. This will force
the fuel beneath the injector plunger out,
thus moving the injector plunger
downwards.
3.
Then screw the adjusting bolt clockwise
until there is clear, considerable resistance.
Do not turn the adjusting bolt further in
clockwise direction to avoid damage.
5
4.
Turn the adjusting bolt 120 anti-clockwise.
This equals a clearance of 0.55 mm (setting
value may be between 0.50 and 0.75 mm).
5.
Hold the adjustment bolt in this position and
tighten the lock nut to the specified
tightening torque, see "Technical data".
3-12
95XF series
M2137
M2138
M2139
 200424

Advertisement

Table of Contents
loading

Table of Contents