DAF 95XF Maintenance Manual page 71

Hide thumbs Also See for 95XF:
Table of Contents

Advertisement

EXPLANATORY NOTES ON THE MAINTENANCE ACTIVITIES
95XF series
Adjusting the valve clearance
1.
Slacken the lock nut of the adjusting bolt.
2.
Using a feeler gauge and special tool (DAF
no. 1240043), adjust the specified valve
clearance, see "Technical data".
3.
Tighten the adjusting bolt using special tool
(DAF no. 1240043) before removing the
feeler gauge.
The specified torque is 0.56 - 0.68 Nm.
4.
Hold the adjusting bolt in this position, and
tighten the lock nut using special tool (DAF
no. 1240042) to the specified tightening
torque, see "Technical data".
 200424
Inspection and adjustment
M2140
5
M2141
3-11

Advertisement

Table of Contents
loading

Table of Contents